M5Stack TVOC/eCO2 Gas Unit (SGP30), Karbonmonoksid (CO), Hvit, Plast, DC, 24 mm, 13 mm
FBAC4895-B52C-4E03-B099-A6A8F8B8017B Created with sketchtool. 706D6907-81E1-46A2-B8F9-7B702A1EF2C7 Created with sketchtool. 6A870209-E7F5-44F5-A66F-09E20C85A0DC Created with sketchtool. 0BB04D6C-A9AB-4913-BF4F-5A23954E68E1 Created with sketchtool. 501E26C7-66C1-4DAA-B740-6CFAF55A1B39 Created with sketchtool. C105F7D3-D5EE-43C9-9EE8-05CC42B296D4 Created with sketchtool. D94689D8-7CBB-41C8-AC06-F79D81FF82D5 Created with sketchtool. DA4C7ED9-2512-4D52-94F0-92800F2A6E04 Created with sketchtool. 42E133FD-828F-4CF4-A0BF-560014487A57 Created with sketchtool. F52D9745-4BFD-4506-BEEF-630FD09EF2D9 Created with sketchtool.
NYTT NAVN. SAMME STORE UTVALG!   NYTT NAVN. SAMME STORE UTVALG!   NYTT NAVN. SAMME STORE UTVALG!
NYTT NAVN. SAMME STORE UTVALG!   NYTT NAVN. SAMME STORE UTVALG!   NYTT NAVN. SAMME STORE UTVALG!
NYTT NAVN. SAMME STORE UTVALG!   NYTT NAVN. SAMME STORE UTVALG!   NYTT NAVN. SAMME STORE UTVALG!
CS MEGASTORE
NYTT NAVN. SAMME MEGA STORE UTVALG!
www.computersalg.no er nå www.csmegastore.no
Les mer
NYTT NAVN. SAMME STORE UTVALG!  NYTT NAVN. SAMME STORE UTVALG!
NYTT NAVN. SAMME STORE UTVALG!  NYTT NAVN. SAMME STORE UTVALG!
NYTT NAVN. SAMME STORE UTVALG!  NYTT NAVN. SAMME STORE UTVALG!
CS MEGASTORE
NYTT NAVN.
SAMME MEGA STORE UTVALG!
www.computersalg.no er nå
www.csmegastore.no
Les mer
Fjernlager
Varen er på fjernlager, leveringstiden er 4-6 hverdager. Mere info

Frakt 69,00 - Instabox - Velg din nærmeste pakkeboks.

Fraktprisen er basert på levering til dette postnummer: - Skift postnummer
Oppgi postnummer for levering. Lagre
Se alle alternativer
Instabox - Velg din nærmeste pakkeboks69,00
Bring - Hentes på Posten75,00
PorterBuddy - Fleksibel hjemlevering - levert på døren på kvelden159,00
Bring - Fleksibel hjemlevering - Levering til døren (om kvelden i større byer)224,00
NOK 199,00
eksklusiv MVA 159,20
Totalt inkl. frakt 268,00
TVOC/eCO2 mini Unit is a digital multi-pixel gas sensor unit with integrated SGP30. It mainly measures various VOC (volatile organic compounds) and H2 in the air. It can be programmed to detect TVOC (total volatile organic compounds) and eCO2 (equivalent carbon dioxide reading)Concentration measurement. Typical measurement accuracy is 15% within the measurement range, the SGP30 reading is internally calibrated and output, which can maintain long-term stability. SGP30 uses I2C protocol communication with on-chip humidity compensation function, which can be turned on through an external humidity sensor. If you need to obtain accurate results, you need to calibrate according to a known measurement source. SGP30 has a built-in calibration function. In addition, eCO2 is calculated based on the concentration of H2 and cannot completely replace "true" CO2 sensors for laboratory use.