Tripp Lite PDUMH20HVAT, Målte, 1U, Horisontal, Metall, Sort, 10 AC-utganger
FBAC4895-B52C-4E03-B099-A6A8F8B8017B Created with sketchtool. 706D6907-81E1-46A2-B8F9-7B702A1EF2C7 Created with sketchtool. 6A870209-E7F5-44F5-A66F-09E20C85A0DC Created with sketchtool. 0BB04D6C-A9AB-4913-BF4F-5A23954E68E1 Created with sketchtool. 501E26C7-66C1-4DAA-B740-6CFAF55A1B39 Created with sketchtool. C105F7D3-D5EE-43C9-9EE8-05CC42B296D4 Created with sketchtool. D94689D8-7CBB-41C8-AC06-F79D81FF82D5 Created with sketchtool. DA4C7ED9-2512-4D52-94F0-92800F2A6E04 Created with sketchtool. 42E133FD-828F-4CF4-A0BF-560014487A57 Created with sketchtool. F52D9745-4BFD-4506-BEEF-630FD09EF2D9 Created with sketchtool.
NYTT NAVN. SAMME STORE UTVALG!   NYTT NAVN. SAMME STORE UTVALG!   NYTT NAVN. SAMME STORE UTVALG!
NYTT NAVN. SAMME STORE UTVALG!   NYTT NAVN. SAMME STORE UTVALG!   NYTT NAVN. SAMME STORE UTVALG!
NYTT NAVN. SAMME STORE UTVALG!   NYTT NAVN. SAMME STORE UTVALG!   NYTT NAVN. SAMME STORE UTVALG!
CS MEGASTORE
NYTT NAVN. SAMME MEGA STORE UTVALG!
www.computersalg.no er nå www.csmegastore.no
Les mer
NYTT NAVN. SAMME STORE UTVALG!  NYTT NAVN. SAMME STORE UTVALG!
NYTT NAVN. SAMME STORE UTVALG!  NYTT NAVN. SAMME STORE UTVALG!
NYTT NAVN. SAMME STORE UTVALG!  NYTT NAVN. SAMME STORE UTVALG!
CS MEGASTORE
NYTT NAVN.
SAMME MEGA STORE UTVALG!
www.computersalg.no er nå
www.csmegastore.no
Les mer
Fjernlager (15-24 hverdager)
Varen er på fjernlager, leveringstiden er 15-24 hverdager. Mere info

Fri frakt - Hentes på Posten.

Se alle alternativer
Bring - Hentes på PostenGratis
Bring - Fleksibel hjemlevering - Levering til døren (om kvelden i større byer)224,00
NOK 11.888,00
eksklusiv MVA 9.510,40
Totalt inkl. frakt 11.888,00
200-240V 20A Automatic Transfer Switch (ATS) / Local Metered PDU (Agency de-rated to 16A continuous)
Provides a redundant power option for critical networking equipment with a single input power cord
2 digit display reports output power consumption in amps
1U horizontal rackmount form factor; 14.8 in. / 37.6 cm depth
10 outlets (8 C13, 2 C19)
Set of Plug-lock output power cable retention sleeves prevent accidental disconnection of connected devices
Set of two C20 inlets support connection to separate PRIMARY and SECONDARY power sources
Two 12-ft. / 3.6m C19 to C20 power cables included
ATS circuits normally maintain output sourced from the primary input cable; As primary input power fails or becomes unstable, the ATS will switch to maintain output sourced from the secondary input cable until power on the primary input is restored and stable
ATS configurations enable fault-tolerant, hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system (in a two-UPS environment, the primary input cable must be supported by an online UPS with zero transfer time similar to Tripp Lite SmartOnline series)
Advanced ATS configurations utilizing separate mains circuits, backup generators and even separate out of phase utility power grid feeds are fully supported
On-board ATS processor constantly evaluates power quality on both inputs to prevent transfer to the secondary source when unavailable or of lower quality than the primary source
Super-fast switchover between primary and secondary power sources occurs in 2-5 milliseconds
Built-in card slot supports optional SNMPWEBCARD or WEBCARDLX for permanent upgrade to a switched & monitored PDU system
Outlets are factory programmed for sequential turn-on at 250 millisecond intervals when the PDU is first energized to prevent inrush-related equipment interaction on startup
Front panel LEDs confirm power availability on both input lines
Federal Trade Agreements Act / TAA Compliant for GSA Schedule purchases