APC Symmetra LX 12kVA Scalable to 16kVA N+1 - Strømarray (kan monteres i rack) - AC 208/240 V - 12000 VA - Ethernet 10/100 - utgangskontakter: 13 - 19U - 19" - svart, sølv
FBAC4895-B52C-4E03-B099-A6A8F8B8017B Created with sketchtool. 706D6907-81E1-46A2-B8F9-7B702A1EF2C7 Created with sketchtool. 6A870209-E7F5-44F5-A66F-09E20C85A0DC Created with sketchtool. 0BB04D6C-A9AB-4913-BF4F-5A23954E68E1 Created with sketchtool. 501E26C7-66C1-4DAA-B740-6CFAF55A1B39 Created with sketchtool. C105F7D3-D5EE-43C9-9EE8-05CC42B296D4 Created with sketchtool. D94689D8-7CBB-41C8-AC06-F79D81FF82D5 Created with sketchtool. DA4C7ED9-2512-4D52-94F0-92800F2A6E04 Created with sketchtool. 42E133FD-828F-4CF4-A0BF-560014487A57 Created with sketchtool. F52D9745-4BFD-4506-BEEF-630FD09EF2D9 Created with sketchtool.
NYTT NAVN. SAMME STORE UTVALG!   NYTT NAVN. SAMME STORE UTVALG!   NYTT NAVN. SAMME STORE UTVALG!
NYTT NAVN. SAMME STORE UTVALG!   NYTT NAVN. SAMME STORE UTVALG!   NYTT NAVN. SAMME STORE UTVALG!
NYTT NAVN. SAMME STORE UTVALG!   NYTT NAVN. SAMME STORE UTVALG!   NYTT NAVN. SAMME STORE UTVALG!
CS MEGASTORE
NYTT NAVN. SAMME MEGA STORE UTVALG!
www.computersalg.no er nå www.csmegastore.no
Les mer
NYTT NAVN. SAMME STORE UTVALG!  NYTT NAVN. SAMME STORE UTVALG!
NYTT NAVN. SAMME STORE UTVALG!  NYTT NAVN. SAMME STORE UTVALG!
NYTT NAVN. SAMME STORE UTVALG!  NYTT NAVN. SAMME STORE UTVALG!
CS MEGASTORE
NYTT NAVN.
SAMME MEGA STORE UTVALG!
www.computersalg.no er nå
www.csmegastore.no
Les mer
Ikke på lager
Varen er ikke på lager.

Bring (Home Delivery) - Hjemlevering - Levering til nærmeste fortauskant.

Utsolgt

Varen er ikke på lager.

NOK 250.554,00
eksklusiv MVA 200.443,20
Totalt inkl. frakt 250.554,00
Gi meg beskjed når varen er på lager igjen.
Modular design
Provides fast serviceability and reduced maintenance requirements via self-diagnosing, field-replaceable modules.

Configurable for N+1 internal redundancy
Provides high availabilty through redundancy by allowing configuration with one more Power Module than is necessary to support the connected load.

Redundant Intelligence Modules
Provides higher availability to the UPS connected loads by giving redundant communication paths to critical UPS functions.

Hot-swappable intelligence modules
Ensures clean, uninterrupted power to protected equipment during Intelligence Module replacement.

Hot-swappable power modules
Ensures clean, uninterrupted power to protected equipment during Power Module replacement.

Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced

Power Modules connected in parallel
Enhances availability by allowing immediate, seamless recovery from isolated module failures.

Battery modules connected in parallel
Delivers higher availability through redundant batteries.

Automatic internal bypass
Supplies utility power to the connected loads in the event of a UPS overload condition or fault.

Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power.